1. Current Location: Home >  Comprehensive classification >  The ceiling AP in the living room has been installed in two suites. The avoidance of access openings and lamps is more important than the placement.

The ceiling AP in the living room has been installed in two suites. The avoidance of access openings and lamps is more important than the placement.

Schematic diagram of ceiling mounted AP in living room: Roof line, maintenance opening, light fixture avoidance and three types of unsuitable houses

When the second apartment was being renovated, the electrician gestured on the roof of the living room and asked me: 「This network cable passes through the beam. Do you want to leave a ceiling AP position for you? 」I was stunned for a moment, remembering all the losses I suffered in my first apartment. The set was a dining room and living room, an open space of about 40 square meters. The router was placed on the TV cabinet. There were only two signal bars at the dining table, and video calls were always blurry. Later, I added a Mesh sub-router, and it worked fine for half a year. Later, I added a sweeper base station at home, and some things were piled under the sub-router, and the coverage shrank again. In my new house, I installed the ceiling AP directly through wiring in the ceiling, and I have been using it for more than a year now. The middle one also installed one of the sets for my cousin, but the pitfalls are different, so I will talk about the two sets together.

Make it clear first: Ceiling APs and panel APs are not alternatives.

The first time many people come into contact with AC+AP, they are attracted by the panel AP. Once the 86 box is turned on, the network port on the wall becomes WiFi, and each person has one in the bedroom and living room. When I was researching the solution for my first apartment, I thought panel AP was the only form. It wasn’t until I went to a friend’s company and saw the ceiling AP on the ceiling that I realized it.: This thing can be bought for home use, and the price is about the same as a panel AP, one hundred and fifty to two hundred.

The division of labor between the two things is actually different. The panel AP is mounted on the wall, and the signal is spread into the room from the height of the wall, which is suitable for A closed room with four walls , like a bedroom or study room, you can reach the bedside through half the wall. The ceiling AP is hung on the ceiling about 2.6 meters tall, with the antenna facing downwards. It is suitable for open space without walls ——In places such as dining and living rooms, corridors, and open kitchens, the coverage area of ​​a ceiling AP can cover two or three panels, and the signal is sent from a high position and does not penetrate the wall. The attenuation mainly comes from the human body and the obstruction of furniture, which is much cleaner than the path of sticking to the wall and passing through the furniture.

The final layout of my house is a mix of things.: There is a ceiling AP pipe on the living room with an open area of ​​40 square meters, and the three bedrooms are still panel APs. How to choose a plan and whether there are these prerequisites for pre-embedded network cables? Comparison between AC+AP and Mesh That article was written in more detail and will not be repeated here. Just say one conclusion: For a house with a large open space, one ceiling tile can support three panels. This account is established.

The wiring step must be fixed before the ceiling is sealed.

The biggest difference between ceiling APs and panel APs is not the signal, but "where the wires come from." The network cable of the panel AP is in the wall, and the decoration electrician routes the cable according to the network port position. This is a routine operation. The network cable of the ceiling AP is top , you have to climb all the way from the weak current box to the center of the top of the living room. The wiring cost of this section is more expensive than that of the wall, and the ceiling must be installed before the ceiling board is sealed. If you want to add the board after the board is sealed, the ceiling must be removed.

What my family did at that time: The weak current box is at the entrance. The network cable comes out of the box and runs through the bottom of the beam, and passes through the keel of the ceiling in the living room. Two meters of redundancy is left in the top, and finally it is led down from the opening in the ceiling. The electrician charged 80 yuan for the work. I checked the continuity of this line and the network port in advance on the day of water and electricity acceptance. I have written an article before about things that should be handled on the day of water and electricity acceptance. Decoration network pre-embedded acceptance list , here is a special feature for the ceiling: The network cable has to be routed through the roof Near the maintenance port , don't let the carpenter nail the wire to the keel, leave a little room for movement, you will thank this decision later.

What my cousin did was another lesson. The suspended ceiling in her house is a flat gypsum board. At that time, she thought it would be troublesome and did not use the ceiling line. When she wanted to install a ceiling AP, the master gave her a compromise plan.: The AP is not installed on the top, but installed on The top of the entrance cabinet faces the living room , the cabinet is two meters high, the effect is 20% off but there is no need to move the top. This can be regarded as a remedy for not using the top line, and it can be done, but the signal diagram and the real ceiling are not the same thing - if you want a fully equipped version, the line must be topped before the board is closed.

Whether to leave the inspection opening?: I advise you to stay

When installing a ceiling-mounted AP on a suspended ceiling, the merchant selling the AP will not take the initiative to tell you about the access opening, let alone the carpenter. Opening an additional opening requires another process. But one of my two apartments was kept and the other was not. The second one was not kept because the AP was installed in the opening on the lower edge of the ceiling, and the machine itself could be removed from below, so I dared not open the access door.

Why is the access hatch important? The AP is a device that hangs on the top. The network port is on the back of the machine, and the POE power supply connector is also on the back. One day, the crystal head is oxidized, the AP is broken and needs to be replaced, or you want to upgrade the WiFi6 machine. There is no access door. You have to remove an entire gypsum board top, putty and paint, and an afternoon's work turns into a three-day project. When I installed the machine at my home, I had the carpenter cut a twenty-by-twenty standard inspection opening thirty centimeters next to the opening, which cost an extra fifty yuan. Later, the AP really had a "good and bad" problem once. When troubleshooting, I reached in through this opening to touch the connector, and pressed the crystal head again. I later saw this fault path once on the panel AP, and the troubleshooting idea is reasonable. That article Troubleshooting when panel AP loses connection in single room There is a complete version inside, and the one on the top is similar to the root of the disease in the wall.

a word: The AP is directly below the opening, and the machine can be dismantled from bottom to top. The access port can be saved. ; The AP is hidden in the flat roof, with only the radome exposed. The inspection opening is a life-saving opening, so don’t save the fifty bucks.

Lamp avoidance: The importance of half a meter

The items in the ceiling are not just APs, but also downlights, light strips, and air-conditioning vents. I was careless about the location arrangement at first. On the drawing, the AP and a downlight were next to each other. After installing the speed test, the southeast corner of the living room was almost one gear slower. Later, the downlight was moved half a meter away before it became normal.

The reason is not complicated. Nowadays, most of the lights in the living room are metal-cased downlights and spotlights. The ceiling AP is installed against it, which is equivalent to setting up a metal baffle next to it. In addition, the lights are driven by switching power supplies. Cheap ones have electromagnetic interference and will affect each other if they are too close. Decorators and plumbers all know this truth, just like audio cables should be kept away from strong electricity. Just remember one thing in practice: The AP center point is at least half a meter away from the nearest metal housing lamp, preferably one meter away. . Before sealing the ceiling board, place the downlight position, AP position, and air outlet position on the drawing. Moving the positions at this stage is zero cost.

There is also a pit in the opposite direction: In order to center the AP, some people installed it directly under the central air conditioner or on the air outlet. The internal unit is a metal shell plus a motor, which is much more powerful than a downlight. When laying out the ceiling, directly cross out the area of ​​the indoor unit, and move the AP from the position of the indoor unit toward the center of the living room. It would rather be one meter away than close to the indoor unit.

A POE wire is used in the weak current box.

The ceiling AP does not need to be connected to the power supply. A network cable comes from the AC all-in-one machine in the weak current box. Both power and data are on this cable. This is POE power supply. For ceiling-mounted equipment, this is not an option, it is the only solution - there is no outlet on the ceiling, and you can't maintain it if it is. At the other end of the weak current box is the POE port of the AC all-in-one machine. Just plug it in and you're done.

Trapped in a weak current box space and cooling . The AC all-in-one machine is thicker than the optical modem router, and a bundle of top-line panel cables are all collected in the box. The weak current box in the first house I rented could not fit in, so I directly replaced it with a larger box. The process is written Replace weak current box I mentioned in detail how to measure the dimensions and how to make the holes. Before installing a ceiling AP, take a look at your own weak current box: Whether the AC all-in-one machine, possibly the switch, the optical modem, and the router can be laid flat together, and whether the box door can be closed is a prerequisite, otherwise all the rest will be in vain.

POE also has a hidden benefit that few people mention.: It is convenient to power off and restart the equipment on the top. Just unplug the POE cable from the weak current box and plug it in again. There is no need to move a ladder. There are many smart devices at home, and the AP restarts occasionally. The order and wait for device reconnection are very particular. I wrote an article before. Dozens of smart home routers According to the analysis, the logic of reconnection storm is the same, and staggered power supply is the most stable.

Which houses should not be bothered with ceilings?

After talking about how good it is to absorb the top all the way, let’s pour some cold water on it at the end. In the following three situations, if you buy the ceiling, you will waste your money, so don’t bother with it.:

house condition why not suitable A more appropriate way
Rough simple decoration without ceiling The open line is ugly and there is no place to hide the AP. Place AP on the top of the tall cabinet to shoot downwards, or directly Mesh
The living room itself is small, with many doors and walls The open space is small and the advantages of ceiling coverage cannot be used Panel AP is enough, one for each room
rented house Moving the suspended ceiling constitutes damage to the decoration and the deposit will not be guaranteed. The sub-router uses cable return, and you can take it with you when you return the lease.

Take your seats and finish, and give the order of actions according to the state of the house.: If you are renovating, before sealing the board, put the top line in, leave the inspection opening, and line up the AP position and lamp position on the drawing. Do these three things right at once. ; If the decoration has been completed and there is a suspended ceiling but no wiring, we will accept the 20% discount plan. The top of the cabinet should be installed or not installed. ; If there is no ceiling and no wiring, don’t force it on. Take the Mesh route. The applicable scenarios of Mesh are clearly explained in the comparison article. The value of a ceiling AP never depends on the signal parameter table, but on whether the 30 centimeters of carpentry work on the roof of your home has been arranged in advance.

Read More


Copyright Notice Scan to read on mobile
All Rights Reserved: 《SHUNOT》 => 《The ceiling AP in the living room has been installed in two suites. The avoidance of access openings and lamps is more important than the placement.》