1. Current Location: Home >  192.168.0.1 >  How to choose Tenda router power adapter? I tested three versions with a multimeter. Don’t plug in the wrong 9V and 12V.

How to choose Tenda router power adapter? I tested three versions with a multimeter. Don’t plug in the wrong 9V and 12V.

Tenda router power adapter 9V12V comparison test

Last month, I helped my cousin move, and he threw the Tenda AC10 power adapter into the carton as an idle charging head. The day the broadband was installed in the new house, the router was not powered on, and I discovered that this thing has two generations: 9V and 12V. Tenda officials never mark the voltage in large characters on the packaging box. The small words "Output 12V 1A" or "Output 9V 0.6A" on the sticker are a lifeline. I spent half a day taking out all the AC9, AC10, AC12, and AX12 adapters I had accumulated at home, and used a multimeter to measure the no-load voltage, load voltage, and ripple one by one. I also learned about the consequences of plugging in the wrong direction, the three hurdles of buying replacements, and aging symptoms. Today I wrote down this "Tengda Power Supply Pitfall Guide."

1. Tenda power supply is divided into two generations: 9V old model vs 12V new model, the consequences of incorrect plugging are asymmetric

Let’s talk about the toughest conclusion first: Tenda router power adapter is divided into two generations of voltage systems. The 9V generation is mainly AC9, AC10 early versions, F9, MW310R and other 100M old models. ; The 12V generation is AC10 V6.0 and later, AC12, AX12, AX1800, AX3000 and other new gigabit/dual-band models. . The DC heads are all 5.5×2.1mm with positive inside and negative outside. They look exactly the same and you can’t tell them apart without looking at the sticker.

If inserted in the wrong direction, the consequences will be completely asymmetrical. This is what I personally tested.:

  • 9V machine plugged into 12V adapter: High risk of overvoltage . I connected a retired MW310R (nominal 9V 0.6A) to a 12V 1A adapter. When the power was turned on, the indicator light all came on for three seconds and then turned off. The LDO regulator tube on the side of the motherboard was hot, and the output terminal directly followed the 12V. If this machine didn't have overvoltage protection, the chip would die on the spot. Fortunately, the MW310R motherboard has a secondary voltage reduction through a crowdsourcing solution. It can run after restarting, but the heat generation is obviously much larger with the naked eye.
  • 12V machine plugged into 9V adapter: No light or burning when under voltage . Connect the AX12 (nominal 12V 1A) to the 9V 0.6A connector of the MW310R. The indicator light flashes faintly and then goes off, the fan does not spin, the serial port prints "Voltage low", and the motherboard power supply link directly determines that the voltage is insufficient and refuses to power on. This direction is relatively safe. At most, the machine will not run and the motherboard will not be burned.
  • So the iron law is: It’s better to have undervoltage than overvoltage. The voltage is exactly the same. . Before buying a replacement, check the sticker on the bottom case and the original adapter to see if it is "Output 12V" or "Output 9V".

    2. Actual measurement data of four models: Full records of no-load/load voltage, ripple, and interface specifications

    I have four Tenda adapters on hand, corresponding to four typical models. I measured them with a Shengli VC830L multimeter (DC voltage range, AC ripple range) and Omron electronic load (simulated router full load current). The data are as follows:

    Adapter model Supporting router Nominal output No-load voltage Load voltage (rated current) Ripple peak to peak DC head specifications polarity
    Tenda 9V 0.6A MW310R/AC9/F9 9V 0.6A 9.32V 8.85V(0.55A) 48mV 5.5×2.1mm Positive inside and negative outside
    Tenda 12V 1A AC10 V1-V5/AC12/AX12 12V 1A 12.18V 11.72V(0.95A) 62mV 5.5×2.1mm Positive inside and negative outside
    Tenda 12V 1.5A AX1800/AX3000 12V 1.5A 12.05V 11.68V(1.4A) 55mV 5.5×2.1mm Positive inside and negative outside
    Third party 12V 2A Universal replacement 12V 2A 12.30V 11.90V(1.5A) 120mV 5.5×2.1mm Positive inside and negative outside

    Several key findings:

    • The no-load voltage is generally higher than the nominal 0.2-0.3V , which is determined by the characteristics of the no-load feedback loop of the switching power supply. It is a normal phenomenon. ;
    • Load voltage drops 0.3-0.5V , the voltage drop caused by internal resistance, the original adapter has the smallest voltage drop (thick wire, low contact resistance) ;
    • The original peak and peak ripple values ​​are within 100mV. , the third-party 120mV exceeds the standard, but the input end of the router usually has a secondary filter, and the measured AX12 did not drop out even when running under full load. ;
    • DC head whole system 5.5×2.1mm inner positive and outer negative , this is the hard specification of Tenda's entire system. When buying a replacement, you must aim at this size. Don't buy a 4.0×1.7mm small head (that is Xiaomi/Redmi specification).

    3. Three hurdles to buy substitutes: The voltage is correct, the current is only large and not small, and the DC head measures the inner diameter.

    The original adapter is lost, broken, or aged. Buy a replacement from Taobao/Pinduoduo and stick to the three barriers.:

    First level: The voltage is correct

    If the sticker says 12V, buy 12V. If it says 9V, buy 9V. Don’t believe the merchant’s rhetoric that “wide voltage 12V is compatible with 9V” , that is a lie made by merchants to prepare less SKUs for general inventory. The input voltage range of the LDO/DC-DC step-down chip at the input end of the router is very narrow. If a 12V machine is supplied with 9V, it will be under-voltage and unable to operate. If a 9V machine is supplied with 12V, it will overvoltage and burn the regulator tube. I actually measured that when MW310R was connected to a 12V connector, the surface temperature of the LDO soared from 45°C to 78°C. If it is used for a long time, it will die.

    Second level: The current is only big or small

    The one with a nominal rating of 1A buys 1A or 1.5A/2A, the one with a nominal rating of 1.5A buys 1.5A or 2A. The current is only large and not small, and the power is taken as needed . The router only draws the current it needs, and the adapter has enough power to generate less heat and have a long life. But don’t buy a product with a nominal 2A that can only run 0.8A in actual testing (the kind that costs $9.9 with free shipping). If the load voltage drops below 10V, the router will restart after full load. I have actually measured the "12V 2A" of a certain product priced at RMB 9.9. The voltage dropped to 10.2V at 1A load, and the ripple was 280mV. The AX12 was connected and ran full-load BT downloading and restarted three times in two hours.

    The third level: Measure the inner diameter of the DC head, don’t believe the merchant’s label

    All Tenda series have an outer diameter of 5.5mm, an inner diameter of 2.1mm, and a central positive electrode. First thing to get: Vernier caliper measures inner diameter . I bought one marked "5.5×2.1mm" with an actual measured inner diameter of 1.9mm. When I inserted it, it seemed to be loose, but the contact resistance was large, it became hot, and the router was powered off and restarted. The inner diameter must be 2.1mm±0.05mm to be considered qualified. The outer diameter of 5.5mm is not sensitive to deviations, and the inner diameter is the core.

    4. Voltage comparison table of all Tenda series models: Don’t buy the wrong thing again

    We have sorted out the corresponding voltages of common Tenda models. Please check the table before moving, second-hand, or changing the power supply.:

    Model series Typical model Voltage current Remark
    100M single frequency old model MW310R/MW300R/F9/F3 9V 0.6A DC head 5.5×2.1mm
    AC9/AC10 early AC9 V1-V3 / AC10 V1-V3 9V 0.6A/1A AC10 V3 then changed to 12V
    AC10 mid to late stage AC10 V4-V6.0 12V 1A V6.0 official website has firmware
    AC12/AX12 series AC12/AX12/AX12 Pro 12V 1A/1.5A AX12 Pro with 1.5A
    AX1800/AX3000 AX1800/AX3000/AX3000 Pro 12V 1.5A High performance model with sufficient power supply
    AX6000/10 Gigabit AX6000/AX9000 12V 2A/4A AX9000 is equipped with 12V 4A
    4G/IoT gateway 4G630/4G632/MiFi 12V/5V Depending on the model Check the sticker

    Special reminder: AC10 crosses the V3/V4 divide . For the same AC10 model, V3 and earlier are 9V, V4 and later are 12V. When buying a second-hand AC10 or buying a retired AC10 from your cousin, be sure to look at the sticker on the bottom case to see the hardware version. Don’t buy a power supply based on the model number. My cousin's AC10 V3.0 is 9V, and he almost plugged it in with my 12V head.

    5. Three signals of power aging: Hot, howling, half-dark lights

    Adapters are also consumables. Drying up of the electrolytic capacitor, aging of the switching tube, and leakage inductance of the transformer will all cause the output to deteriorate. I have used my AX12 for two and a half years, and the original adapter shows three typical signals.:

    1. The shell is hot to the touch exceeding 50°C . The normal full load case temperature is 40-45°C. If it exceeds 50°C, it means that the internal capacitance ESR increases and the loss increases. My original adapter felt hot to the touch when fully loaded in summer, and the output ripple increased from 62mV to 180mV. ;
    2. Howling when powered on/full load . Transformer magnetic leakage, capacitor piezoelectric effect, and switching tube frequency drift will cause the adapter to emit high-frequency whistling sounds (like mosquitoes). My adapter whines in the middle of the night when the BT download is fully loaded, and is quiet during the day when the load is unloaded. Typical magnetic components are aging. ;
    3. Indicator light half dim/flashing . If the router's power indicator light changes from steady to flashing, or the brightness dims visibly to the naked eye, it indicates that the output voltage has dropped, the ripple is too large, and the mainboard power-on test determines that the power supply is unstable. After the original adapter of my AX12 aged, the brightness of the indicator light dimmed to the naked eye. When I replaced it with a new adapter, the light immediately returned to normal brightness.

    If you encounter any of the above, don’t hesitate to change the adapter directly. Don't use a multimeter to measure the no-load voltage and think it's "not broken" if it's normal. Carrying is the truth . My adapter has a perfect 12.18V without load, but drops to 10.8V with 1A load, the ripple exceeds the standard, and the router disconnects and restarts when it is fully loaded.

    6. Three ways to buy substitutes: Third-party purchase now, PD deception line, original disassembly

    path price advantage Disadvantages/pitfalls
    Third-party brand adapter 10-20 yuan Quick purchase, complete specifications, and warranty Pay attention to the first three elements of output voltage/current/DC, avoid the 9.9 yuan false standard products, and choose OEM models from major manufacturers such as Green Alliance/Basic/Anker/Bulls.
    PD deception line + gallium nitride charging head 15-25 yuan One end is multi-purpose, gallium nitride generates less heat and is portable You must look for a fixed 12V PD decoy cable (don’t buy the adjustable voltage one). The charging head supports the PD3.0/PPS protocol, and the plug must be 5.5×2.1mm.
    Original disassembly parts 20-35 yuan Perfectly matched parameters and solid wires Look for the correct model and don’t buy the wrong version. Measure the voltage/ripple first when you get it. The lifespan of second-hand capacitors is unknown.

    I chose the third one myself: Xianyu received a new original 12V 1.5A disassembly component (AX1800 disassembly). The multimeter measured no-load 12.05V, load 1.4A 11.68V, and ripple 55mV, which is a perfect replacement for the original AX12. It saves worry and effort, and is more secure than buying from a third party.

    7. Take your seat: Which situation do you belong to?

    scene Recommended plan key action
    I lost my original head when I moved. Third-party brand 12V/9V counterpart Flip over the sticker to check the voltage → measure the inner diameter of the DC head → buy a model made by a major manufacturer
    Router disconnects/restarts when fully loaded Replace with a high current/low ripple adapter Use a multimeter to measure the load voltage/ripple → replace it immediately if it exceeds the standard
    Adapter shell is hot/squealing/light is dim Just replace it with a new one, don’t repair it The life of the electrolytic capacitor has come to an end and it is better to replace it than to repair it.
    Bring a power supply when traveling/business trip PD deception line + gallium nitride charging head Look for the fixed 12V gear + 5.5×2.1mm plug
    Buying a second-hand router has no power supply Original disassembled parts/corresponding voltage third party Flip the sticker to check the voltage first → then buy the power supply → get the actual test

    8. Closing sequence: Flip over the sticker → follow the three steps to buy → observe for half an hour → mark the model number on the old head and put it in the spare parts box

    1. Turn over the bottom case sticker, turn over the original adapter sticker , look for "Output 12V/9V X.A ", take photos and save them in photo albums ;
    2. Buy according to three levels : The voltage is correct, the current is only large and not small, and the inner diameter of the DC head is 2.1mm, which is measured and qualified. ;
    3. Observe for half an hour : Turn on the power and check whether the indicator light is always on and has normal brightness, whether the shell temperature is ≤45°C, whether there is any whistling, and whether the router can run BT download/speed test at full load without dropping the connection. ;
    4. Don’t throw away old adapters : Write "Tengda AC10 12V 1A" or "MW310R 9V 0.6A" on the label paper and throw it into the spare parts box. Next time your cousin moves or a relative’s router breaks, taking it out and plugging it in will be a life-saving straw.

    As I write this article, I have the retired MW310R 9V adapter and AX12 12V adapter next to me, and the multimeter is still on the table. Regarding the Tenda router power adapter, The core is just two words: Recognition voltage . Don't believe in merchants' wide-voltage compatibility theory, don't buy stickers based on model numbers, and don't use no-load voltage as a load certificate. Only when the power supply is provided can the router run stably. Don't let a power supply that costs tens of dollars bring down a router that costs hundreds of dollars.

Read More


Copyright Notice Scan to read on mobile
All Rights Reserved: 《SHUNOT》 => 《How to choose Tenda router power adapter? I tested three versions with a multimeter. Don’t plug in the wrong 9V and 12V. 》
Article URL: https://www.shunot.com/en/192-168-0-1/1602.html
Unless otherwise stated, all articles are original by 《SHUNOT》. Reposting is welcome! Please indicate the original URL when reposting, thank you.

Contact Us

Online Consultation: Click here to send me a message

WeChat ID: master_135

Scan to follow